Displaced Volume
Gallons Liters*
Primary Secondary Primary Secondary
5 4 19 15
*Please Note: Standard prover volume is in gallons, liters are optional. Prover requires non-standard switchbar for liters. Alternate displaced volumes are available for liters, please contact factory for additional information. Liters are a direct conversion and not indicative of Seraphin can sizes.

FMD-007 Small Volume Prover Dimensions
Pressure Rating A B C D E F G H J K L M N P Q R S T U U*
150# 46.57 39.50 123.25 29 43 35.25 97 30 30 69 18 1 19.63 30 7.88 38 15.13 40.25 6.38 11.38
300# 46.57 39.50 123.25 29 43 35.25 97 30 30 69 18 1 19.63 30 7.88 38 15.13 40.25 7.88 11.38
600# 46.57 39.50 123.25 29 43 35.25 97 30 30 69 18 1 19.63 30 7.88 38 15.13 40.25 8.25 11.38
900# 46.57 39.50 123.25 29 43.88 34.38 97 30 30 70 19 2 20.38 30 8.38 37.15 15.13 41.13 9.38 14.38
Drawings Notes:
*FMD-007 Right Side Flange
1. Dimensions “K” and “L” are for center of gravity within 6 inches. 2.Spacial dimensions have a tolerance of 1.00 inches. 3. Dimension “P” is inlet-to-outlet flange distance, drains and vents may vary. 4. All FMD-130 600# and FMD-200 models have 8 lifting lugs. Table gives dimensions to outermost lugs. 5. All dimensions are subject to change without notice. 6. For TT configurations see specific outline.

FMD-007 Weights ANSI Pressure – 150# ANSI Pressure – 300# ANSI Pressure – 600# ANSI Pressure – 900#
Weight +/- 5% LBS KGS LBS KGS LBS KGS LBS KGS
1,730 790 1,755 800 1,780 810 2,000 910
Weight with Crate +/- 5% 2,130 966 2,155 977 2,180 989 2,400 1,089
Weight filled with Water +/- 5% 1,830 830 1,855 841 1,880 853 2,100 953

FMD 007 – Motor Voltage – Phase Availability – Amperage Draw
Motor HP 24 VDC 120 VAC 220 VAC 220 VAC 208-230 VAC 240 VAC 440 VAC 460 VAC
Single Phase Single Phase 3 Phase 3 Phase 3 Phase 3 Phase 3 Phase
50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 60 Hz 60 Hz
1.0 28 10.6 5.3 3.2 3.2 3.2 1.5 1.5