FMD-090EV Meter Prover

FMD090EV EXTENDED VOLUME METER PROVER

FMD’s latest addition to its proving family is the state-of-the-art Extended Volume Prover Line. The FMD-090EV small volume meter prover is designed specifically for proving manufactured pulse meters such as Coriolis, ultrasonic and helical turbine meters. With a 50% greater volume capacity, at 120 gallons compared to 80 gallons for the standard FMD-090, the FMD-090EV allows for larger sample sizes and extended flight times making it the ideal choice for proving manufactured pulse meters.

SPECIFICATIONS

ADDITIONAL SPECIFICATIONS

Displaced Volume – FMD-090EV
Gallons Liters*
Primary Secondary Primary Secondary
120 80 450 340
*Please Note: Standard prover volume is in gallons, liters are optional. Prover requires non-standard switchbar for liters. Alternate displaced volumes are available for liters, please contact factory for additional information. Liters are a direct conversion and not indicative of Seraphin can sizes.
FMD-090EV Small Volume Prover Dimensions (inches)
Pressure Rating A B C D E F G H J K L M N P Q R S T U
Min Max
150# 59.62 58.21 287.75 51.50 119.75 64 120 32 111 30 141 34 1 37.75 82.25 27 64 14 126 19.13
300# 59.62 58.21 287.75 51.50 119.75 64 120 32 111 30 141 34 1 37.75 82.25 27 64 14 126 19.75
600# 59.62 58.21 287.75 51.50 119.75 64 120 32 111 30 141 34 1 37.75 82.25 27 64 14 126 21.25
900# Please contact factory for dimensions
Drawings Notes:All dimensions are shown in inches. 1. Dimensions “K” and “L” are for center of gravity within 6 inches. 2.Spacial dimensions have a tolerance of 1.00 inches. 3. Dimension “P” is inlet-to-outlet flange distance,
drains and vents may vary. 4. All FMD-130 600# and FMD-200 models have 8 lifting lugs. Table gives dimensions to outermost lugs. 5. All dimensions are subject to change without notice. 6. For TT configurations see specific
outline. 7. Dimension “H” max is the distance required to remove fully assembled piston assembly from the prover. Complete seal change may be done with piston not completely removed which requires 32”.
FMD-090EV Weights ANSI Pressure – 150# ANSI Pressure – 300# ANSI Pressure – 600# ANSI Pressure – 900#
Weight +/- 5% LBS KGS LBS KGS LBS KGS LBS KGS
11,625 5,275 11,816 5,360 12,010 5,450 15,600 7,080
Weight with Crate +/- 5% 13,080 5,935 13,271 6,020 13,465 6,110 17,055 7,740
Weight filled with Water +/- 5% 13,425 6,090 13,616 6,180 13,810 6,270 17,400 7,900
FMD-090EV Motor Voltage – Phase Availability – Amperage Draw
Motor HP 120 VAC 220 VAC 208-240 VAC 380-400 VAC 440-480 VAC
1 Phase 1 Phase 3 Phase 3 Phase 3 Phase
50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz
2.0 22 11.6 8.6 5.2 2.9

FMD-090EV Approvals and Certifications

ISO 9001:2015, 17025:2005
CE Mach Dir:2006/42/EC, EN 12100-2:2003
ATEX 2014/34/EU II 2(1)G Ex db mb [ia Ga] IIB T3 Gb / -20 °C to +40 °C / Cert#: CSANe 25ATEX1007X
CSA (US & Canada) Class I, Division 1, Groups C and D, Class I Division 2, Groups C and D – Maximum Operation Ambient 60°C – Class I, Division 1, Group D, Class I, Division 2, Group D – Maximum Operation Ambient 40°C – Cert#: 2137671
IECEx Ex db mb [ia Ga] IIB T3 Gb / -20 °C to +40 °C / Cert#: IECEx CSA 25.0009X
ABSA CRN: OF1072.2

As with all FMD provers, the FMD-090EV exceeds the accuracy standards required by API MPMS Chapter 4 and delivers best-in-class performance. This advanced meter prover provides 12″ ANSI flanges, 2″ drains/vents and ports for verifying pressure and temperature. Flow MDs small volume provers provide exceptional performance, quality, and field durability, making the FMD090EV an exceptional choice for all of your proving applications.

  • Designed for a wide range of liquid measurement applications (see our Applications Specific Prover Page or our Frequently Asked Questions for additional application information).
  • All FMD Provers conform to API MPMS Chapter 4 Standards
  • Materials of Construction: Stainless Steel – 304 or 316, Duplex Steel
  • Standard flange size: 12″ ANSI B16.5
  • 2″ drain flanges, 2″ thermowell vents

KEY FMD PROVER BENEFITS