FMD-200EV Extended Volume Meter Prover

FMD-200EV EXTENDED VOLUME METER PROVER

FMD’s latest addition to its prover family is the state-of-the-art Extended Volume Prover Line. The FMD-200EV small volume meter prover is designed specifically for proving manufactured pulse meters such as Coriolis, ultrasonic, and helical turbine meters. With a 50% greater volume capacity, 210 gallons in comparison to 140 gallons for the standard FMD-200, the FMD-200EV allows for larger sample sizes and extended flight times, making it the ideal choice for proving manufactured pulse meters.

SPECIFICATIONS

ADDITIONAL SPECIFICATIONS

Displaced Volume – FMD-200-EV50
Gallons Liters*
Primary Secondary Primary Secondary
210 170 800 640
*Please Note: Standard prover volume is in gallons, liters are optional. Prover requires non-standard switchbar for liters. Alternate displaced volumes are available for liters, please contact factory for additional information. Liters are a direct conversion and not indicative of Seraphin can sizes.
FMD-200-EV50 Small Volume Prover Dimensions (inches)
Pressure Rating A B C D E F G H J K L M N P Q R S T U
Min Max
150# 73.59 71.98 309.00 64 121 76.75 132 42 138 30 163 39 1 45.36 93 13.75 69.75 17.25 135 25.75
300# 73.84 71.98 337 64 128.13 97.50 132 42 137 30 173 39 2 45.50 93 18.50 69.63 17.25 140 26.38
600# 76.26 71.98 346.50 64 134.13 100.50 132 42 132 30 CF* CF* 2 46.75 92.50 21.75 94.25 17.63 147.38 29.60
900# Please consult factory for dimensions
Drawings Notes:
Drawing Notes: All dimensions are shown in inches. 1. Dimensions “K” and “L” are for center of gravity within 6 inches. 2.Spacial dimensions have a tolerance of 1.00 inches. 3. Dimension “P” is inlet-to-outlet flange distance,
drains and vents may vary. 4. All FMD-130 600# and FMD-200 models have 8 lifting lugs. Table gives dimensions to outermost lugs. 5. All dimensions are subject to change without notice. 6. For TT configurations see specific
outline. 7. Dimension “H” max is the distance required to remove fully assembled piston assembly from the prover. Complete seal change may be done with piston not completely removed which requires 42”.
This information is coming soon – In the mean time, please consult factory for weights 
FMD-200-EV50 Weights ANSI Pressure – 150# ANSI Pressure – 300# ANSI Pressure – 600#
Weight +/- 5% LBS KGS LBS KGS LBS KGS
21,600 9,800 24,800 11,250 34,970 15,865
Weight with Crate +/- 5% 26,150 11,865 29,350 13,320 39,520 17,930
Weight filled with Water +/- 5% 26,800 12,200 30,000 13,610 40,170 18,220
FMD-200-EV50 Motor Voltage – Phase Availability – Amperage Draw
Motor HP 208-230 VAC 220 VAC 240 VAC 380 VAC 400 VAC 440 VAC 460 VAC 480 VAC
3 Phase 3 Phase 3 Phase 3 Phase 3 Phase 3 Phase 3 Phase 3 Phase
50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz
7.50 19 19 19 11 11 9.5 9.5 9.5

FMD-200-EV50 Approvals and Certifications

ISO 9001:2015, 17025:2017
CE Mach Dir:2006/42/EC, EN 12100-2:2003
ATEX 2014/34/EU II 2(1)G Ex db mb [ia Ga] IIB T3 Gb /-20 °C to + 40 °C / Cert#: CSANe 25ATEX1007X Iss 1
CSA (US & Canada) Class I, Division 1, Groups C and D, Class I Division 2, Groups C and D – Maximum Operation Ambient 60°C – Class I, Division 1, Group D, Class I, Division 2, Group D – Maximum Operation Ambient 40°C – Cert#: 213767
IECEx Ex db mb [ia Ga] IIB T3 Gb / -20 °C to + 40 °C / Cert#: IECEx CSA 25.0009X
ABSA CRN: OF1072.2

As with all FMD provers, the FMD-200EV exceeds the accuracy standards required by API MPMS Chapter 4 and delivers best-in-class performance. This advanced meter prover provides 20″ ANSI flanges, 2″ drains/vents and ports for verifying pressure and temperature. Flow MDs small volume provers provide exceptional performance, quality, and field durability, making the FMD-200EV an exceptional choice for all of your proving applications.

  • Designed for a wide range of liquid measurement applications (see our Applications Specific Prover Page or our Frequently Asked Questions for additional application information).
  • All FMD Provers conform to API MPMS Chapter 4 Standards
  • Materials of Construction: Stainless Steel – 304 or 316, Duplex Steel
  • Standard flange size: 20″ ANSI B16.5
  • 2″ drain flanges, 2″ thermowell vents

KEY FMD PROVER BENEFITS